Part Number Hot Search : 
DF1508M DS18S20Z BT405 CXA1511L SW101 200CA 2SK21 PE4188
Product Description
Full Text Search
 

To Download LA55-TP Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Current Transducer LA 55-TP
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN =
50 A
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance @ with 12 V with 15 V ISN KN VC IC Vd Vb X @ 50 A max @ 70 A max @ 50 A max @ 70 A max 50 0 .. 70 TA = 70C TA = 85C RM min RM max RM min RM max 10 10 50 50 100 50 160 90 60 95 60 1) 60 1) 135 155 135 2) 135 2) A A
Features
*Closed loop (compensated) current
transducer using the Hall effect

*Printed circuit board mounting *Insulated plastic case recognized
according to UL 94-V0.
Secondary nominal r.m.s. current Conversion ratio Supply voltage ( 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn R.m.s. rated voltage
50 mA 1 : 1000 12 .. 15 V 10 (@ 15 V) + IS mA 2 kV 60 V
Advantages
*Excellent accuracy *Very good linearity *Low temperature drift *Optimized response time *Wide frequency bandwidth *No insertion losses *High immunity to external
interference
Accuracy - Dynamic performance data
Accuracy @ IPN , TA = 25C
L
@ 15 V ( 5 %) @ 12 .. 15 V ( 5 %)
Linearity Offset current @ IP = 0, TA = 25C Residual current 3) @ IP = 0, after an overload of 3 x IPN Thermal drift of IO 0C .. + 70C - 25C .. + 85C Reaction time @ 10 % of IP max Response time 4) @ 90 % of IP max di/dt accurately followed Frequency bandwidth (- 1 dB)
0.65 0.90 < 0.15 Typ Max 0.2 0.3 0.5 0.6
% % % mA mA mA mA ns s A/s kHz
*Current overload capability.
IO IOM IOT tra tr di/dt f
Applications
*AC variable speed drives and servo
motor drives
0.1 0.1
< 500 <1 > 200 DC .. 200
*Static converters for DC motor drives *Battery supplied applications *Uninterruptible Power Supplies
(UPS)
*Switched Mode Power Supplies
(SMPS)
General data
TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ Mass Standards - 25 .. + 85 - 40 .. + 90 80 85 24 EN 50178 C C g
*Power supplies for welding
applications.
TA = 70C TA = 85C
5)
Notes :
1) 2) 3) 4) 5)
Measuring range limited to 60 A max Measuring range limited to 55 A max Result of the coercive field of the magnetic circuit With a di/dt of 100 A/s A list of corresponding tests is available
980706/4
LEM Components
w w w .lem.com
Dimensions LA 55-TP
Bottom view
(in mm. 1 mm = 0.0394 inch)
Left view
Secondary terminals
Terminal + : supply voltage + 12 .. 15 V Terminal - : supply voltage - 12 .. 15 V Terminal M : measure
Connection
Standard 00 or N SP..
Year Week
Front view Mechanical characteristics
*General tolerance *Fastening & connection of primary
Recommended PCB hole *Fastening & connection of secondary Recommended PCB hole 0.2 mm bus bar 6.4 x 1.6 mm 3.8 mm 3 pins 0.63 x 0.56 mm 0.9 mm
Remarks
*IS is positive when IP flows in the direction of the arrow. *Temperature of the primary conductor should not exceed
90C.
*This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...), please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.


▲Up To Search▲   

 
Price & Availability of LA55-TP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X